- General Information
- Manufacturer
- Eaton Corporation
- Manufacturer Website Address
- http://www.eaton.com
- Brand Name
- Eaton
- Product Series
- 93PX
- Product Type
- Double Conversion Online UPS
The 93PX double-conversion online UPS 208V (5-20kW) and 400V (15kW / 20kW) offers simple, reliable, and cost-effective power for edge and data center environments. With plug-and-play deployment, high-efficiency, 1.0 power factor, advanced cybersecurity, and scalable redundancy, it ensures continuous protection, surge resistance, and auto-restart-ideal for critical applications requiring high performance and operational resilience.
- Warranty
- Limited Warranty
- 2 Year
- Technical Information
- Plug/Connector Type
- Hardwired
- Receptacle Type
- Hardwired
- Protection Type
- Backfeed
- Surge
- Phase
- Three Phase
- Application/Usage
- Data Center
- IT Infrastructure
- Switch
- Server
- Healthcare
- Hospital
- Medical
- IT Rack
- Mission Critical Equipment
- Edge Computing
- Network
- Server Room
- Network Closet
- Clinic
- Medical Equipment
- Crest Factor
- 3:1
- Efficiency
- 98.8%
- Power Description
- Load Capacity (Watt)
- 15 kW
- Input Voltage
- 380 V AC
- 400 V AC
- 415 V AC
- Input Voltage Range
- 173 V AC - 520 V AC
- 277 V AC - 520 V AC
- Output Voltage
- 380 V AC
- 220 V AC
- 400 V AC
- 230 V AC
- 415 V AC
- 240 V AC
- Input Frequency
- 50 Hz
- 60 Hz
- 45 Hz
- 55 Hz
- 54 Hz
- 66 Hz
- Output Frequency
- 50 Hz
- 45 Hz
- 55 Hz
- Input Current
- 32 A
- Waveform Type
- Pure Sine Wave
- Output Power Factor
- 1
- Display & Graphics
- Display
- LCD
- Management
- Network Management
- RS-232
- Network-M3 Card
- INDGW-M3 Card
- INDGW-M2 Card
- Interfaces/Ports
- Serial Port
- Yes
- USB
- Yes
- EPO Port
- Yes
- Battery Information
- DC System Voltage
- 240 V DC
- Battery Characteristics
- Valve-regulated
- Battery Chemistry
- Lead Acid
- Battery Capacity
- 9000 mAh
- Number of External Battery Cabinets
- 2
- Backup/Run Time With External Battery Cabinet (Full Load)
- 2.50 Minute
- Backup/Run Time With External Battery Cabinet (Half Load)
- 9.50 Minute
- Typical Battery Recharge Time
- 3 Hour
- Environmental Conditions
- Maximum Operating Temperature
- 104°F (40°C)
- Storage Temperature
- 5°F (-15°C) - 140°F (60°C)
- Maximum Operating Elevation
- 3280 ft
- Physical Characteristics
- Form Factor
- Rack-mountable
- Rack Height
- 12U
- Miscellaneous
- Package Contents
- Power Module (PM)
- Maintenance Bypass Panel (MBP)
- 2 x Extended Battery Modules (EBMs)
- TAA Compliant
- No
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)